中文Tel: +86-755-85290629

Service & Support | JAPAN UNIX Soldering Robots

1. Service Scope

We provide repair, maintenance, on-site/factory inspection, fault-code diagnosis and program recovery for the following models:

This series consists of JAPAN UNIX desktop automatic soldering robots, widely used for spot and drag soldering of connectors, terminals and PCB pads. The 412/413/414 are different specifications of the same series and R/G/S are different configurations. Repair and parts cover all models listed above; specific parts are matched according to the machine nameplate.

We also undertake repair and parts for other models currently sold: UNIX-410R automatic soldering robot and DF desktop soldering robot.

2. Why Choose Us: Complete Parts, Shorter Downtime

  • Readily available original-specification wear parts: soldering tips (D/V/N and other tip types), heaters (matched to original specifications by model), feeder nozzles and tubes, tip up/down sensors, heater cables, A boards, teaching pendants/panels, motor drive power supplies, emergency stop buttons and I/O modules, etc. — fast delivery and short downtime.
  • Post-repair burn-in testing of the whole machine: we ensure the four core functions — return to origin, solder feeding, temperature control and communication — all work normally before delivery.
  • JAPAN UNIX Authorized Service Provider: all repairs use JAPAN UNIX genuine parts; inspection and factory standards are consistent; every repair is documented and a test report is included with delivery.

3. Common Faults and Solutions

3.1 Daily Faults (Robot Does Not Start / Solder Feeding / Temperature Control)

SymptomCommon CauseSolution
Robot does not start (does not return to origin)Power cable not properly inserted; in emergency-stop stateCheck the power cable connection; release emergency stop and press START
Moves to a position different from the taught positionWrong program number; teaching error; soldering-unit screw looseVerify the taught program number; re-teach; tighten the soldering-unit screw to avoid position deviation
Robot stops during solderingSolder clogging (SOLDER TRBLE) / solder run-out (SOLDER OUT) / emergency-stop signal / pause / READY lamp off / incorrect soldering-condition teachingClear the clog and re-insert solder, replace the solder reel; release emergency stop/pause and press START; verify soldering conditions (especially the tip up/down selection dn/Up and displacement output So for drag soldering)
Solder feeding is poor, clogging occurs frequentlySoot on the nozzle tip; poor solder wire engagement in the feeder; improper solder supply position; solder feed speed too fast during solderingSoak the nozzle in alcohol to remove soot; refer to correct feed adjustment for engagement; adjust the supply position; reduce the feed speed
TEMP/DATA display flashes 888Heater or heater cable open circuit / poor contactCheck the cable connection; replace the heater or heater cable
TEMP/DATA display flashes ErTip down-end sensor did not actuate within the specified timeCheck the tip down-end sensor; replace it if defective

3.2 Soldering-Related Errors (St1–St7)

After clearing a soldering-related Error, press START and continue from the next key; if solder run-out/clogging/heater alarm, etc. is detected before soldering starts, clear the fault and restart from the same point.

CodeMeaningSolution
St1No SolderSolder wire used up; replace with new solder wire
St2Feed Solder (solder clogging)Feeder nozzle clogged or supply position incorrect; re-check
St3Heater is not ready (heater alarm)Heater/sensor open circuit; replace with a new heater
St4Soldering Unit Not ReadyTemperature has not reached the set value or the up/down sensor has not actuated (also occurs when STOP/CLR is held down); check the heater, up/down sensor and heater leads
St5Unit Communication Error 1Soldering controller DATA SET switch is ON or communication line fault; check the switch, COM2 communication settings and connecting leads
St6Unit Communication Error 2Hardware failure; repair required
St7Heater abnormalityHeater/sensor/lead open circuit; replace the heater

3.3 Initialization / Axis Errors (Er89–Er99)

During initialization, if the specified Pulse has acted but the sensor is open/not shielded, the corresponding axis sensor or motor is abnormal (sensor abnormality when the motor moves, motor abnormality when it does not); if the specified Pulse has acted but there is no Z-phase signal / a constant output from the driver, the 0-phase of that axis driver is abnormal.

CodeAxisDescription
Er89 / Er90Z axisSensor/motor abnormality; driver 0-phase abnormality
Er92 / Er93X axisSensor/motor abnormality; driver 0-phase abnormality
Er95 / Er96Y axisSensor/motor abnormality; driver 0-phase abnormality
Er98 / Er99R axisSensor/motor abnormality; driver 0-phase abnormality

3.4 Operation / System Errors

CodeMeaningSolution
001Specified number has not been taughtSpecify a program number with taught content
006Point type abnormalityCheck the point type and input again (e.g. a CP continuous pass point after PTP)
007Position out of rangePoint is outside the range specified by Soft Limit; verify the position
008Specified point operation abnormalityCheck the point operation content (conditional calculation / Then-Else / Wait, etc.) and input again
009No Then/Else after If conditionCheck the point operation content and input again
010No Endif after IfCheck the point operation content and input again
011No endWait after WaitCondCheck the point operation content and input again
012No Label target value for JumpCheck the point operation content and input again
013GoPoint has no Point number specifiedError when the target point number is out of range or negative; verify the command
016Specified Palette abnormalityCheck the Palette specified by the point attribute and input again
022CP speed OverReduce the line speed (CP speed)
037Motor drive power supply abnormalityMotor drive power not switched on; check the connector connection or the power supply itself
042–045CallJob/CallProg call abnormalityCheck the called Job/Prog number and nest level (error if over 30)
046–053For/do, Local, equation, IO/COM, Parameter abnormalityCheck point operation commands, variable definitions, parentheses and parameter ranges
082Emergency stop occurredAfter releasing emergency stop, press Start / F4 / the start signal for the corresponding mode to enter initialization standby or the original state
100Theoretical ErrorPower the unit On again; contact the service provider if it recurs
101Trap ErrorReplace the A board
Long 1 / Long 2 / Short 2–5System/board abnormality (judged by buzzer pattern)Long 1 = replace A board; Long 2 = reload system program; Short 2–5 = Board check abnormality, replace the A board if necessary

4. Repair Process

  1. Request: provide the model, fault symptom or Error code, years of use and on-site photos/videos.
  2. Inspection: power-on self-check + fault-code reading + item-by-item check of axis/temperature control/communication to locate the root cause.
  3. Quotation: a diagnosis report and parts list are issued; work starts after confirmation, with no additional charges.
  4. Repair: replace genuine parts, re-teach or restore the program if necessary.
  5. Burn-in test: run points continuously to verify the four core functions — return to origin, solder feeding, temperature control and communication.
  6. Delivery: a test report and routine maintenance recommendations are included to reduce repeat failures.

5. Spare Parts in Stock (Complete)

  • Soldering tips: common tip types such as D / V / N
  • Heaters: matched to original specifications by model
  • Solder-feeding mechanism: feeder nozzles, feed tubes, feed wheel assemblies
  • Sensors: tip up/down sensors, axis origin/limit sensors
  • Electrical parts: heater cables, A boards, motor drive power supplies, I/O modules
  • Operating parts: teaching pendants/panels, emergency stop buttons, START key assemblies

The above parts are kept in stock; specific models are matched according to the machine nameplate. Special parts can be dispatched quickly to shorten downtime.

6. Frequently Asked Questions

Q: Are repair parts for the 412R and 414R interchangeable?
A: The 412/413/414 are the same series and R/G/S are different configurations; parts interchangeability falls into three categories:

  • Drives and power supplies: not interchangeable between 412 and 413/414; interchangeable between 413 and 414.
  • Wear parts (soldering tips, heaters, solder-feeding mechanism, sensors, etc.): fully interchangeable across 412/413/414; repair covers all models listed.
  • Boards: the same board is common to all three, but after installation the travel parameters must be modified via software to suit the corresponding model — it is not plug-and-play.

Exact part models are matched according to the machine nameplate.

Q: What should I do if TEMP/DATA flashes 888?
A: It is usually an open circuit or poor contact of the heater or heater cable. First check the cable connection; after confirming an open circuit, replace the heater or heater cable to restore temperature control.

Q: Solder keeps clogging (SOLDER TRBLE / St2)?
A: First check soot on the nozzle tip, solder-feed engagement, solder supply position and feed speed — soak in alcohol to remove soot, adjust engagement and supply position, and reduce the feed speed. See the 3.1/3.2 solution tables above.

Q: Axis errors such as Er89 / Er92?
A: During initialization, the sensor/motor or driver 0-phase of the corresponding axis (Z/X/Y/R) is abnormal; repair that axis motor, sensor or driver specifically. See 3.3.

JAPAN UNIX Authorized Service Provider · Genuine Parts · Every repair documented and reported