We provide repair, maintenance, on-site/factory inspection, fault-code diagnosis and program recovery for the following models:
This series consists of JAPAN UNIX desktop automatic soldering robots, widely used for spot and drag soldering of connectors, terminals and PCB pads. The 412/413/414 are different specifications of the same series and R/G/S are different configurations. Repair and parts cover all models listed above; specific parts are matched according to the machine nameplate.
We also undertake repair and parts for other models currently sold: UNIX-410R automatic soldering robot and DF desktop soldering robot.
| Symptom | Common Cause | Solution |
|---|---|---|
| Robot does not start (does not return to origin) | Power cable not properly inserted; in emergency-stop state | Check the power cable connection; release emergency stop and press START |
| Moves to a position different from the taught position | Wrong program number; teaching error; soldering-unit screw loose | Verify the taught program number; re-teach; tighten the soldering-unit screw to avoid position deviation |
| Robot stops during soldering | Solder clogging (SOLDER TRBLE) / solder run-out (SOLDER OUT) / emergency-stop signal / pause / READY lamp off / incorrect soldering-condition teaching | Clear the clog and re-insert solder, replace the solder reel; release emergency stop/pause and press START; verify soldering conditions (especially the tip up/down selection dn/Up and displacement output So for drag soldering) |
| Solder feeding is poor, clogging occurs frequently | Soot on the nozzle tip; poor solder wire engagement in the feeder; improper solder supply position; solder feed speed too fast during soldering | Soak the nozzle in alcohol to remove soot; refer to correct feed adjustment for engagement; adjust the supply position; reduce the feed speed |
| TEMP/DATA display flashes 888 | Heater or heater cable open circuit / poor contact | Check the cable connection; replace the heater or heater cable |
| TEMP/DATA display flashes Er | Tip down-end sensor did not actuate within the specified time | Check the tip down-end sensor; replace it if defective |
After clearing a soldering-related Error, press START and continue from the next key; if solder run-out/clogging/heater alarm, etc. is detected before soldering starts, clear the fault and restart from the same point.
| Code | Meaning | Solution |
|---|---|---|
| St1 | No Solder | Solder wire used up; replace with new solder wire |
| St2 | Feed Solder (solder clogging) | Feeder nozzle clogged or supply position incorrect; re-check |
| St3 | Heater is not ready (heater alarm) | Heater/sensor open circuit; replace with a new heater |
| St4 | Soldering Unit Not Ready | Temperature has not reached the set value or the up/down sensor has not actuated (also occurs when STOP/CLR is held down); check the heater, up/down sensor and heater leads |
| St5 | Unit Communication Error 1 | Soldering controller DATA SET switch is ON or communication line fault; check the switch, COM2 communication settings and connecting leads |
| St6 | Unit Communication Error 2 | Hardware failure; repair required |
| St7 | Heater abnormality | Heater/sensor/lead open circuit; replace the heater |
During initialization, if the specified Pulse has acted but the sensor is open/not shielded, the corresponding axis sensor or motor is abnormal (sensor abnormality when the motor moves, motor abnormality when it does not); if the specified Pulse has acted but there is no Z-phase signal / a constant output from the driver, the 0-phase of that axis driver is abnormal.
| Code | Axis | Description |
|---|---|---|
| Er89 / Er90 | Z axis | Sensor/motor abnormality; driver 0-phase abnormality |
| Er92 / Er93 | X axis | Sensor/motor abnormality; driver 0-phase abnormality |
| Er95 / Er96 | Y axis | Sensor/motor abnormality; driver 0-phase abnormality |
| Er98 / Er99 | R axis | Sensor/motor abnormality; driver 0-phase abnormality |
| Code | Meaning | Solution |
|---|---|---|
| 001 | Specified number has not been taught | Specify a program number with taught content |
| 006 | Point type abnormality | Check the point type and input again (e.g. a CP continuous pass point after PTP) |
| 007 | Position out of range | Point is outside the range specified by Soft Limit; verify the position |
| 008 | Specified point operation abnormality | Check the point operation content (conditional calculation / Then-Else / Wait, etc.) and input again |
| 009 | No Then/Else after If condition | Check the point operation content and input again |
| 010 | No Endif after If | Check the point operation content and input again |
| 011 | No endWait after WaitCond | Check the point operation content and input again |
| 012 | No Label target value for Jump | Check the point operation content and input again |
| 013 | GoPoint has no Point number specified | Error when the target point number is out of range or negative; verify the command |
| 016 | Specified Palette abnormality | Check the Palette specified by the point attribute and input again |
| 022 | CP speed Over | Reduce the line speed (CP speed) |
| 037 | Motor drive power supply abnormality | Motor drive power not switched on; check the connector connection or the power supply itself |
| 042–045 | CallJob/CallProg call abnormality | Check the called Job/Prog number and nest level (error if over 30) |
| 046–053 | For/do, Local, equation, IO/COM, Parameter abnormality | Check point operation commands, variable definitions, parentheses and parameter ranges |
| 082 | Emergency stop occurred | After releasing emergency stop, press Start / F4 / the start signal for the corresponding mode to enter initialization standby or the original state |
| 100 | Theoretical Error | Power the unit On again; contact the service provider if it recurs |
| 101 | Trap Error | Replace the A board |
| Long 1 / Long 2 / Short 2–5 | System/board abnormality (judged by buzzer pattern) | Long 1 = replace A board; Long 2 = reload system program; Short 2–5 = Board check abnormality, replace the A board if necessary |
The above parts are kept in stock; specific models are matched according to the machine nameplate. Special parts can be dispatched quickly to shorten downtime.
Q: Are repair parts for the 412R and 414R interchangeable?
A: The 412/413/414 are the same series and R/G/S are different configurations; parts interchangeability falls into three categories:
Exact part models are matched according to the machine nameplate.
Q: What should I do if TEMP/DATA flashes 888?
A: It is usually an open circuit or poor contact of the heater or heater cable. First check the cable connection; after confirming an open circuit, replace the heater or heater cable to restore temperature control.
Q: Solder keeps clogging (SOLDER TRBLE / St2)?
A: First check soot on the nozzle tip, solder-feed engagement, solder supply position and feed speed — soak in alcohol to remove soot, adjust engagement and supply position, and reduce the feed speed. See the 3.1/3.2 solution tables above.
Q: Axis errors such as Er89 / Er92?
A: During initialization, the sensor/motor or driver 0-phase of the corresponding axis (Z/X/Y/R) is abnormal; repair that axis motor, sensor or driver specifically. See 3.3.
JAPAN UNIX Authorized Service Provider · Genuine Parts · Every repair documented and reported